Please enter search keywords!

Site Map

Site Map
New! Semight Instruments HV-SPGU S3023P
Date:2023.12.02 Visits:435



The High Voltage Semiconductor Pulse Generator Unit (HV-SPGU) is widely used for testing of advanced non-volatile memories (NVMs). In addition, for transistors with high electron mobility, pulse IV measurements with narrow pulses with fast rising edges are required due to charge trapping effects and the large amount of heat caused by DC measurements, which affects the accuracy of test results.


The Semight Instruments HV-SPGU S3023P offers up to 40V, 30ns fast rising edge, and narrow pulses with 120ns pulse width, making it ideal for advanced non-volatile storage and a wide range of applications requiring fast pulse IV measurements.

 

Product Features


01,High Voltage 


Provides 20V Pulse Voltage, and output short circuit current 800mA (peak current) or 400mA (average current) during +/-40V output voltage with 50Ω loading.



02,Fast Narrow Pulse


Narrow pulse with 120ns pulse width, typical pulse rise time 30ns for output amplitude ≤5V



03,Output Voltage Monitoring


The HV-SPGU's Autput Voltage Monitoring function can measure voltage with an accuracy of 50uV.



04,Supports Tri-level Pulses


Support double-level pulse and Triple-level Pulse output, pulse period 40ns~10s



Product Specification


Item

Test conditions

Technical indicators

Remark

Voltage magnitude

50Ωload

-20V ~ +20V

Open circuit

-40V ~ +40V

Output voltage precision

Open circuit

±0.5%+50mV

Voltage magnitude resolution

50Ω load

0.2mV

|Vout| ≤ 5V

0.8mV

5V ≤|Vout| ≤ 20V

Open circuit

0.4mV

|Vout| ≤ 10V

1.6mV

10V ≤|Vout| ≤ 40V

Output interface

SMA

Internal resistance

50Ω ± 1%

Output short-circuit current

800mA peak value (400mA mean value)

Output overshoot (ring)

50Ω load

±5%+20mV



















Item

Sub-item

Technical indicators

Remark

Frequency scope

0.1 ~ 33MHz  

Pulse cycle

Programmable scope

40ns ~ 10s

Resolution

10ns

Minimum cycle

100ns

( Vout ≤ 10V)

Precision

±1%0.01%+200ps

Pulse width

Programmable scope

20nS ~ (pulse cycle -10ns)

Resolution

2.5ns

Vamp<10V

20ns

Vamp>10V

Minimum value(10%~90% edge)

120nS (60ns typical value)

Precision

±3%+2ns

Pulse process time (Tr and Tf)

Programmable scope

20ns ~ 400ms

Resolution

2ns

Tr+Tf≤10us

20ns

Tr+Tf10us

Minimum value (10%~90% edge)

30ns

Vamp≤ 5V

35ns

Vamp≤ 10V

40ns

Vamp≤ 20V

60ns

Vamp≤ 20V

Precision

-5%~+5%+25ns

Vamp≤ 10V

-5%~+5%+40ns

Vamp≤ 20V

Item

Sub-item

Technical indicators

Remark



















































































Log in

Account number

Password

Register an account

Name

Please enter your name *

Email

Please enter your email address *

Email verfication code

Please enter your email verification code

Phone

Please enter your contact number *

Password

Please enter your login password *

Confirm Password

Please enter your login password again *
Retrieve password

e-mail address

Please enter your email number *

Email verification code

Please enter your email verification code

New Password

Please enter your login password *

Confirm Password

Please enter your login password again *